| Overview The Building Code of New Zealand sets out minimum ventilation requirement for industrial and commercial premises. However depending on the building use this can be less than adequate. It is generally recognised that workplace efficiency is improved when ventilation matches the interior conditions. Extracting oppressively hot air and fumes minimises worker lethargy, loss of concentration, and consequent loss of productivity. Even in colder weather, effective air circulation improves the workplace environment, so your investment works all year. |
|||||||||||||||||||||||||||||||||
|
Round Vane (RV) Industrial Range Ampelair RV Industrial Ventilators are engineered and constructed to require very little maintenance even after years of service. With their low profile design and aluminium construction, Ampelair ventilators are designed to give optimum efficiency through the angle of the vane and the enlarged surface area. Even in cross winds the vane shape will retain its rotational strength. Features
Dampers
Manual and Electronically operated dampers are available for most sizes. Please contact your nearest Ampelite office for more information. Warranty
Ampelair Round Vane (RV) ventilators feature a 10 year warranty. For full warranty details, please download a copy of the Ampelair RV brochure or contact your nearest Ampelite office.
|
Round Vane (RV) Industrial Range |
||||||||||||||||||||||||||||||||
|
Straight Vane (SV) Industrial Range Features
Dampers Warranty
|
Straight Vane (SV) Industrial Range |
||||||||||||||||||||||||||||||||
Vent Capacity Table
| VENT CAPACITY TABLE | |||||||
|---|---|---|---|---|---|---|---|
|
STACK |
WIND SPEED Km/hr |
TEMP DIFF °C |
|
||||
|
150 |
300 |
450 |
600 |
900 |
|||
|
3 |
6 |
6 |
0.04 |
0.15 |
0.35 |
0.61 |
1.62 |
|
12 |
0.04 |
0.16 |
0.36 |
0.63 |
1.67 |
||
|
18 |
0.04 |
0.17 |
0.38 |
0.66 |
1.76 |
||
|
8 |
6 |
0.05 |
0.18 |
0.42 |
0.73 |
1.93 |
|
|
12 |
0.05 |
0.18 |
0.43 |
0.74 |
1.1.96 |
||
|
18 |
0.05 |
0.19 |
0.45 |
0.79 |
2.09 |
||
|
12 |
6 |
0.07 |
0.27 |
0.63 |
1.09 |
2.89 |
|
|
12 |
0.07 |
0.28 |
0.64 |
1.11 |
2.94 |
||
|
18 |
0.07 |
0.28 |
0.64 |
1.12 |
2.96 |
||
|
16 |
6 |
0.08 |
0.34 |
0.77 |
1.34 |
3.56 |
|
|
12 |
0.09 |
0.34 |
0.79 |
1.38 |
3.66 |
||
|
18 |
0.09 |
0.35 |
0.81 |
1.41 |
3.74 |
||
|
6 |
6 |
6 |
0.04 |
0.16 |
0.36 |
0.63 |
1.67 |
|
12 |
0.05 |
0.19 |
0.42 |
0.73 |
1.94 |
||
|
18 |
0.05 |
0.19 |
0.43 |
0.75 |
1.99 |
||
|
8 |
6 |
0.05 |
0.18 |
0.42 |
0.74 |
1.96 |
|
|
12 |
0.05 |
0.19 |
0.44 |
0.76 |
2.03 |
||
|
18 |
0.05 |
0.2 |
0.46 |
0.8 |
2.12 |
||
|
12 |
6 |
0.07 |
0.28 |
0.64 |
1.11 |
2.94 |
|
|
12 |
0.07 |
0.29 |
0.66 |
1.14 |
3.03 |
||
|
18 |
0.07 |
0.31 |
0.71 |
1.24 |
3.29 |
||
|
16 |
6 |
0.09 |
0.34 |
0.79 |
1.38 |
3.66 |
|
|
12 |
0.09 |
0.35 |
0.81 |
1.41 |
3.75 |
||
|
18 |
0.09 |
0.37 |
0.84 |
1.47 |
3.9 |
||
|
9 |
6 |
6 |
0.04 |
0.17 |
0.38 |
0.66 |
1.76 |
|
12 |
0.05 |
0.18 |
0.43 |
0.75 |
1.99 |
||
|
18 |
0.05 |
0.21 |
0.48 |
0.84 |
2.23 |
||
|
8 |
6 |
0.05 |
0.2 |
0.45 |
0.79 |
2.09 |
|
|
12 |
0.05 |
0.21 |
0.46 |
0.8 |
2.12 |
||
|
18 |
0.06 |
0.23 |
0.53 |
0.92 |
2.45 |
||
|
12 |
6 |
0.07 |
0.28 |
0.64 |
1.12 |
2.96 |
|
|
12 |
0.08 |
0.3 |
0.71 |
1.24 |
3.29 |
||
|
18 |
0.08 |
0.32 |
0.74 |
1.28 |
3.4 |
||
|
16 |
6 |
0.09 |
0.35 |
0.81 |
1.41 |
3.74 |
|
|
12 |
0.09 |
0.37 |
0.84 |
1.47 |
3.9 |
||
|
18 |
0.09 |
0.37 |
0.86 |
1.49 |
3.95 |
||
| BUILDING TYPE | RECCOMENDED AIR CHANGES PER HOUR | ||||
|---|---|---|---|---|---|
|
Warehouses |
4 to 8 |
||||
|
Factories and Workshops |
5 to 8 |
||||
|
Gyms Tennis and Squash Courts |
7 to 10 |
||||
|
Assembly Halls, Garages |
10 to 15 |
||||
|
Toilets |
12 to 15 |
||||
|
Laundries |
20 to 40 |
||||
|
Stables, Piggeries and Poultry |
20 to 50 |
||||
|
Bakeries, Boiler Houses |
30 to 40 |
||||
Number of Vents
Calculations to decide the number of vents.
Consideration should be given to the space occupied by stored goods or machinery. The adjustment to volume can reduce the number of vents required by up to 50%.